DMD15/DMD15L IBS/IDR Satellite Modem User Interfaces
TM051 - Rev. 5.8 4-21
+12 Power: {Pass/Fail, No/Yes}
Indicates power supply voltage out of range.
+5 Power: {Pass/Fail, No/Yes}
Indicates power supply voltage out of range.
Battery: {Pass/Fail, No/Yes}
Indicates that internal clock battery is low.
RAM/ROM: {Pass/Fail, No/Yes}
Indicates M&C memory fault.
M&C uProc: {Pass/Fail, No/Yes}
Indicates M&C Microprocessor hardware failure.
UIO Present: {Pass/Fail, No/Yes}
Indicates absence of Universal Input/Output Module
(UIM) Hardware
IF Present: {Pass/Fail, No/Yes}
Indicates absence of IF hardware detect.
Ext Ref Lock: {Pass/Fail, No/Yes}
Indicates that the External Reference PLL is not locked.
Ext EXC Act: {Pass/Fail, No/Yes}
Indicates that the External Clock is not active.