Radyne DMD15L Instrucciones de operaciones Pagina 107

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 118
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 106
RCS20 M:N Redundancy Switch Appendix B
TM056 Rev. 2.3 B-7
radOperatingMode OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
test_pattern_2_15(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Test Pattern Operating Mode:
None,
(2^15)-1
"
::= { radSNMP_Mod_NV_Status 28 }
radCarrierTest OBJECT-TYPE
SYNTAX INTEGER {
off(0),
cw(1),
dual(2),
offset(3),
posfir(4),
negfir(5)
}
ACCESS read-write
STATUS current
DESCRIPTION
"off, turns carrier off
cw, causes the modulator to output pure carrier
dual, causes a double sideband output
offset, causes a single side band output
posfir, uses a positive FIR
negfir, uses a negative FIR"
::= { radSNMP_Mod_NV_Status 29 }
radCircuitID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (11))
ACCESS read-write
STATUS optional
DESCRIPTION
"Provides entry of Tx circuit identifier. Circuits can be given up
to 11 character alphanumeric identity such as LINK1.
Not implemented."
::= { radSNMP_Mod_NV_Status 30 }
radControlMode OBJECT-TYPE
SYNTAX INTEGER {
local(0),
terminal(1),
computer(2),
ethernet(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Selects the active control source.
This is obsolete."
::= { radSNMP_Mod_NV_Status 31 }
radMode OBJECT-TYPE
SYNTAX INTEGER {
directv(9)
Vista de pagina 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 117 118

Comentarios a estos manuales

Sin comentarios