Radyne DMDVB20 LBST Instrucciones de operaciones Pagina 27

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 113
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 26
DMDVB20 LBST Satellite Modem Theory of Operation
TM138 – Rev. 1.0 3-7
Mod Fault: De-energized when any transmit side fault is detected.
Demod Fault: De-energized when any receive side fault is detected.
Common Fault: De-energized when any fault that is not explicitly a Tx or
Rx Fault such as an M&C or Power Supply Fault.
Open Collector Faults:
The UIM provides two Open Collector Faults that appear at Pins 18 & 21 on J19.
Mod Fault: Will sink up to 20 ma (maximum) until a transmit or
common fault is detected. Will not sink current if a fault
is detected.
Demod Fault: Will sink up to 20 ma (maximum) until a receive or
common fault is detected. Will not sink current if a fault
is detected.
The open collector faults are intended for use in redundancy switch applications in order to
provide quick status indications.
3.3 Internal Clock
The time and date is kept in order to ‘time-tag’ system events. User can change the Internal
Clock via the front panel or Terminal ports.
Vista de pagina 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 112 113

Comentarios a estos manuales

Sin comentarios