DMDVB20 LBST Satellite Modem User Interfaces
TM138 – Rev. 1.0 4-25
10 Mbps/HD – for 10 Base-T in either half-duplex or full
duplex.
HW/FW CONFIG (menu)
FIRMWARE REV Displays the installed firmware revision.
M&C REV Displays the installed Monitor and Control revision.
MAIN BOARD (menu)
Only the appropriate of the VCO adjustment screens listed below will be
displayed. These are protected fields, to prohibit accidental changes. To
edit the field, the user must depress all four of the direction arrow keys
simultaneously.
INT VCO ADJUST {0% - 100%}
Allows the user to adjust the internal frequency
reference for calibration. Only displayed of the system
reference clock is INTERNAL.
HI STAB VCO ADJUST {0% - 100%}
Allows the user to adjust the internal frequency
reference for calibration. Only displayed if the system
reference clock source is HI STABILITY.
LARGEST HB GAP Used for factory test only.
SOFT RESET {Enter}
IF BOARD (menu) Indicates the Radyne part number for the IF Board
Assembly.
AGC/CTRL/VALUE {0% - 100%}
Allows the user to adjust the internal frequency
reference for calibration. Only displayed if the system
reference clock source is HI STABILITY.
I OFFSET Used for factory test only.
Q OFFSET Used for factory test only.
LB RX LVL OFFSET Used for factory test only.
POWER SOURCE Used for factory test only.
Comentarios a estos manuales