DM240XR High-Speed Digital Modulator SNMP
MN-DM240XRRevision 13 8–6
qam16(3),
apsk16(9),
apsk32(10)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the modulation type.
Note: Changing modulation type will affect the symbol
rate and data rate. See note at the end of this section."
::= { radSNMPModNVStatus 18}
radFraming OBJECT-TYPE
SYNTAX INTEGER {
dvb(0)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"This selection is reserved and is superceeded by satFraming. Please refer
to radSNMPModNVStatus.69 for more information."
::= { radSNMPModNVStatus 19 }
radReedsolomon OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Enables the ReedSolomon encoder. Reserved"
::= { radSNMPModNVStatus 20 }
radScramblerControl OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Enables scrambler operation"
::= { radSNMPModNVStatus 21 }
radScramblerType OBJECT-TYPE
SYNTAX INTEGER {
dvb(0)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Selects scrambler type.
Not implemented"
::= { radSNMPModNVStatus 22 }
radDifferentialEncoder OBJECT-TYPE
SYNTAX INTEGER {
off(0)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Disables differential encoder
unsupported
"
::= { radSNMPModNVStatus 23 }
radAlarmMaskEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
ACCESS read-write
Vista de pagina 99