DM240XR High-Speed Digital Modulator Remote Operations
MN-DM240XRRevision 13 9–24
Opcode: <2C05h> Command Set Date
<1>
Year
00 – 99
<1>
Month
1 – 12
<1>
Day
1 – 31
Opcode: <2C06h> Command Set Time and Date
<1>
Year
00 – 99
<1>
Month
1 – 12
<1>
Day
1 – 31
<1>
Hour
0 – 23
<1>
Minute
0 – 59
<1>
Second
0 – 59
Opcode: <2F40h> Command RF Redundancy Mode
<1>
Redundancy
Mode
3 = auto-revert, 4 = manual, 5 = backup
Opcode: <2F41h > Command RF Fault Test
<1>
Fault Test
0 = normal, 1 = faulted
Opcode: <2F42h > Command RF Activate Side
<1>
Activate Side
0 = backup, 1 = prime