DM240XR High-Speed Digital Modulator SNMP
MN-DM240XRRevision 13 8–4
SYNTAX INTEGER {
scte(0),
sct(1),
none(2)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects Tx clock source. 0 selects terrestrial clock
(SCTE), 1 selects internal clock (SCT). Modulators using
ASI or G.703 interface options must use SCTE at all
times."
::= { radSNMPModNVStatus 9 }
radFramingMode OBJECT-TYPE
SYNTAX INTEGER {
framing188Byte (0),
framing204Byte (1),
framingNone (2),
framingDirecPc (3),
framingDirecTv (4),
framingProMpegCop3 (5),
framingProMpegAcm (6),
framingBridge (7),
framingDssOverIP (8)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the frame transport stream input type.
Note: Changing the framing mode will affect the symbol
rate and/or data rate. See note at the end of this
section."
::= { radSNMPModNVStatus 10 }
radRolloff OBJECT-TYPE
SYNTAX INTEGER {
rolloff0point35 (0),
rolloff0point20 (1),
rolloff0point25 (25)
}
ACCESS read-write
STATUS current
DESCRIPTION
"0 selects alpha factor rolloff of 0.35,
'1' selects alpha factor rolloff of 0.20,
'25' selects alpha factor rolloff of 0.25"
::= { radSNMPModNVStatus 11}
radFreqReferenceSource OBJECT-TYPE
SYNTAX INTEGER {
internal(0),
external(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects internal or external reference clock"
::= { radSNMPModNVStatus 12 }
radExternalReference OBJECT-TYPE
SYNTAX INTEGER (256000..10000000)
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the external reference frequency in Hz with a
8000Hz step size."
::= { radSNMPModNVStatus 13 }
radInterfaceType OBJECT-TYPE
SYNTAX INTEGER {
serial(0),
asiNorm(2),
asiNull(3),
Vista de pagina 97