Radyne DM240XR Especificaciones Pagina 130

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 196
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 129
DM240XR High-Speed Digital Modulator Remote Operations
MN-DM240XRRevision 13 9–16
Opcode: <2B54h> Command Pilot Symbols
<1>
Pilot Symbols
0=Off, 1=On
Opcode: <2560h> Query RF Switch Status
<1>
Redundancy
Mode
3 = auto-revert, 4 = manual, 5 = backup
<1>
Fault Test
0 = normal, 1 = faulted
<1>
Switch
Connector
0 = backup, 1 = prime
<1>
Online Side
0 = backup, 1 = prime
<1>
Distant Status
0 = normal, 1 = faulted
Opcode: <2601h> Command a Modulator's Configuration
<4>
IF
Frequency
Binary Value, units Hz in 1Hz steps.
50000000Hz to 180000000Hz 70/140
950000000Hz to 2050000000Hz L-Band
<2>
Reserved
TBD
<4>
Data Rate
Binary Value, 1 bps Steps (See note at the end of this
command.)
<4>
External
Reference
Binary Value, units Hz in 8000Hz steps, e.g. 1000000Hz,
1008000Hz, etc.
256000Hz to 10000000Hz
<1>
Frequency
Reference
Source
0 = Internal, 1 = External
<1>
Modulation
Type
0 = QPSK, 1 = BPSK, 2 = 8PSK, 3 = 16QAM, 9 =
16APSK, 10 = 32APSK (See note at the end of this
command.)
<1>
Inner FEC Rate
1 = 1/2 Rate, 2 = 2/3 Rate, 3 = 3/4 Rate, 4 = 5/6 Rate, 5 = 7/8
Rate, 6 = 6/7 Rate, 7=4/5, 8 = 8/9 Rate, 9 = 9/10 Rate, 128 =
1/4 Rate, 129 = 1/3 Rate, 130 = 2/5 Rate, 131 = 3/5 Rate (See
note at the end of this command.)
<1>
Reserved
TBD, Default = 1
<1>
Reserved
TBD, Default = 1
<1>
Reserved
TBD, Default = 0
<1>
Reserved
TBD, Default = 0
<2>
Transmit Power
Level
Signed Value. 0 to 250 (0.0 to 25.0 dBm)
<1>
Carrier Control
0 = Off, 1 = On
<1>
Carrier Type
0 = Normal, 1 = CW, 2 = Dual, 3 = Offset, 4 = Pos FIR, 5 =
Neg FIR
Vista de pagina 129