DM240XR High-Speed Digital Modulator AutoEQ™ Interface Operation Guide
MN-DM240XR– Revision 13 D–14
D.12 Additional Features
D.12.1 AutoEQ™ Status Indicator
The LED on the back of the AutoEQ™ interface card can provide additional status for the
operation of the AutoEQ™ system.
Short Blink Green
Heartbeat, board ready for operation.
Solid Green AutoEQ™ test pattern lock.
Solid Yellow AutoEQ™ data being accessed.
Blink Red AutoEQ™ test pattern unlocked. Signal error.
D.12.2 LNB Power Connector
On the back of the AutoEQ™ interface card is the connector J13 that can be used to insert LNB
power to the J12 SMA connector to feed DC to the LNB.
Mating Connector: PP3-002A 5.5mm x 2.1mm x 9.5mm In-Line DC Power Plug.
(www.cui.com)