Radyne DM240XR Especificaciones Pagina 132

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 196
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 131
DM240XR High-Speed Digital Modulator Remote Operations
MN-DM240XRRevision 13 9–18
Bit 6 = Terr Ethernet jitter buffer underflow
Bit 7 = Terr Ethernet jitter buffer overflow
0 = Mask, 1 = Allow
<1>
Common Fault
Mask
Bit 0 = -12 V Alarm
Bit 1 = +12 V Alarm
Bit 2 = +5 V Alarm
Bit 3 = Spare
Bit 4 = Spare
Bit 5 = Spare
Bit 6 = Spare
Bit 7 = Spare
0 = Mask, 1 = Allow
<1>
Reserved
TBD, Default = 0
<4>
Symbol Rate
Symbol Rate in Symbols Per Second
(See note at the end of this command.)
<1>
Terrestrial
Framing
0 = 188 Byte, 1 = 204 Byte, 2 = No Framing
5 = COP3, 6 = ACM, 7 = Bridge
(See note at the end of this command.)
<1>
Roll Off
0 = 0.35, 25 = 0.25, 1 = 0.20
<1>
Reserved
TBD
<1>
Output Clock
Source
0 = SCTE, 1 = SCT, 2 = None
(See table at the end of this command.)
<1>
Network Spec
0 = DVB-S
9 = DirecTV
11 = DVB-S2-CCM
13 = DirecTV AMC-NBC
15 = DVB-S2-ACM
<1>
BB Scrambler
Bypass
0 = Normal, 1 = Bypass
<1>
Outer FEC
Bypass
0 = Normal, 1 = Bypass
<1>
Test Pattern
0 = None, 1 = 2
15
1, 23 = 2
23
-1
<1>
Last Rate
Control
0 = Symbol Rate, 1 = Data Rate, 2 = Auto
<1>
Interleaver
Bypass
0 = Bypass, 1 = Normal
<1>
PCR
Restamping
0 = Off, 1= On
<1>
Multi-PIIC
Mode
1 = Manual,
2 = Redundancy
Vista de pagina 131